The SMART PFT CO DIFUSSION SYSTEM transfer was developed for swift investigation of CO diffusion capacity. Even with low patient vital capacities (from approx. 0.7 liters), the rapid, very linear gas analyzer can determine diffusion capacity by means of a single breath measurement. Intelligent software reduces the risk of errors by supporting and automating the measurement process.
Designed for simplified CO transfer capacity screening
Nowadays, CO-Diffusion testing has reached a level of importance in pulmonary function testing like never before. Smart PFT CO transfer devices allow comfortable and reliable testing of single breath diffusion capacity for diagnostics and trend screening. Our powerful testing software allows for a full software-triggered measurement sequence, reducing the risk of significant testing failures. Advanced and long-term tested software algorithms help calculate measurements with very small vital capacities. Very selective, accurate, and long-term stable gas analyzers make the device very reliable and nearly maintenance-free. Our 30 years of experience developing full-range lung function testing systems guarantee a high-class and user-friendly product to support your daily testing routine.
Main Features:
• Single breath CO Diffusion System
• CO transfer capacity test fast, linear, and reproducible.
• This device is designed for quick screening of CO-Diffusion capacity.
• Advanced and long-term tested software algorithms help calculate measurements with very small vital capacity starting from approximately 0.7 litres.
• The system registers and displays real-time all-important data like gas concentrations, volume and mouth pressure.
• The test runs fully automatic without any technician intervention for gas release and gives online all necessary advice for the correct breathing manoeuvres.
• Selective and fast infrared gas analyzer measuring transfer and inert gas (CO & CH4)
• Particular and precise gas supply by a demand valve
• Input mask for Hb and COHb values and correlating recalculation of test result.
• Automatic altitude corrections by built in ambient pressure sensor.
• Online display of mouth pressure during breath holding.
• Gas analyzer works without absorber products like expensive naphion sampling line which reduce recurrent maintenance cost.
• Upgradable to Bronchial challenge studies, Respiratory Drive Mechanics Studies, and Body plethysmography Systems.
• Standard Parameters: TLco, Kco, TLC, RV, FRC, VA , t diff, Hb, VIN (ch4)
Available measurement optional:
• Respiratory drive (P0.1/MIP/MEP)
• Airway resistance (ROCC)
• Rhinomanometry
• Compliance
• Challenge testing
• Body box Plethysmography ( upgradable)